What is the function of the fully automatic dosing device


The fully automatic dosing device is a complete automatic dosing device that can mix polyaluminum chloride into a liquid and accurately add it to water. After preparation, the medication will be stored in a storage tank and then added to the prepared dosing point through a metering pump. The fully automatic dosing device consists of two tanks and two pumps, mainly composed of tanks, mixers, motors, brackets, solution buckets, and metering pumps.

1、 Intelligent control of fully automatic dosing device, time-saving and labor-saving

1. The dosing device is controlled by a PLC intelligent control system, with a high degree of automation;

2. The fully automatic dosing device has a fault automatic alarm function, can be connected to industrial Ethernet for network communication, and can monitor equipment and start/stop through the upper computer.

2、 Accurate dosage, stability, and persistence

1. The concentration of the medicine is constant, and the administration is accurate and stable;

全自动加药装置

2. The accessories of the fully automatic dosing device are made of imported parts, which have a long service life;

3. The fully automatic dosing device has a delicate structure, reasonable design, and a small footprint.

How to use a fully automatic dosing device

Users of the fully automatic dosing device configure drugs according to the proportion of the dosing solution and add them through a metering pump.

1. Connect the dosing device, then check each flange interface and tighten it to prevent liquid leakage.

2. Connect the power supply of the metering pump

(1) Open the junction box of the electrical control cabinet and connect the three-phase four wire power line that meets the requirements of the metering pump motor to the corresponding terminal.

(2) Start the mixer instantly by controlling the operation switch, observe the motor rotation, and fix the junction box after correct rotation. If the steering is not correct, adjust the phase sequence before fixing the junction box.

3. Close the discharge valve. Fill the medication container with medication solution.

4. Open the valve of the dosing system and start the metering pump.

Please pay special attention to the fully automatic dosing device:

When the dose is 1. The fully automatic dosing device starts all pipelines corresponding to the metering pump and closes other pipelines.

2. The top of the device is equipped with an overflow pipe to prevent the medicine from overflowing from the sewage pipe.

3. A tubular filter is installed at the inlet of the metering pump to prevent large particles from entering and damaging the metering pump.

Maintenance of fully automatic dosing device

The pipeline of the fully automatic dosing device should be kept unobstructed at all times, and the connection components, filters, inlet and outlet of the device should be inspected regularly and irregularly to observe whether there is any sediment in these components. If these symptoms are found, they should be cleaned up in a timely manner. Regularly inspect the mixing device of the fully automatic dosing device to see if the mixing shaft rotates flexibly, if the impeller is twisted, and if the connecting sleeve is loose, in order to avoid excessive shaft torque and consumption of mixing power. If damaged, replace it promptly.